CVE-2025-1316
CVE-2025-1316 is a critical-severity vulnerability (CVSS 4.0 CVSS-B score 9.3). Edimax IC-7100 IP camera contains an OS command injection vulnerability due to improper input sanitization that allows an attacker to achieve remote code execution via specially crafted requests. CISA added it to the Known Exploited Vulnerabilities catalog on 2025-03-19, with a remediation due date of 2025-04-09 for US federal civilian agencies. As of 2026-11-22, EPSS estimates a 74.5% probability of exploitation in the next 30 days, in the 99th percentile of scored CVEs.
Updated
- CVSS 4.0
- 9.3 CRITICAL
- EPSS
- 74.5% (99th pct)
- CISA KEV
- Exploited
- Published
- 2025-03-04
- Weakness
- CWE-78
Edimax IC-7100 IP Camera OS Command Injection Vulnerability is confirmed as actively exploited and is listed in the CISA KEV catalog.
Required action
Apply mitigations per vendor instructions, follow applicable BOD 22-01 guidance for cloud services, or discontinue use of the product if mitigations are unavailable.
CISA notes
https://www.edimax.com/edimax/post/post/data/edimax/global/press_releases/4801/ ; https://nvd.nist.gov/vuln/detail/CVE-2025-1316
Description
Edimax IC-7100 does not properly neutralize requests. An attacker can create specially crafted requests to achieve remote code execution on the device
Key Findings
as of 2026-11-22- CISA added CVE-2025-1316 to the KEV catalog 15 days after its CVE record was published. The median for entries added in 2025 is 26 days.
- Its current EPSS score (74.5%) is higher than that of 59% of CISA KEV entries.
Severity
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:NOpen in CVSS calculator CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:HOpen in CVSS calculator Remediation Timeline
BOD 26-04, US federal agenciesDeadlines for US federal civilian agencies under Table 1 of CISA BOD 26-04, from the CVE's KEV status (listed) and CISA's SSVC values (automatable yes, technical impact total, 2025-03-19).
How the timeline is set
Table 1 of CISA's Binding Operational Directive 26-04 sets the time US federal civilian agencies have to remediate a vulnerability. It depends on four inputs: whether the asset is publicly exposed, whether the CVE is in the KEV catalog, whether an adversary can automate its exploitation, and whether exploitation gives partial or total control of the asset, which SSVC calls technical impact. CISA publishes the last three for every CVE through services such as its Vulnrichment program.
Days are calendar days. The clock starts at whichever comes first: CISA adds the CVE to the KEV catalog, or the agency identifies the vulnerability on an asset and reports it to its Continuous Diagnostics and Mitigation (CDM) dashboard. A publicly exposed asset is accessible to unauthenticated or untrusted entities via public networks, such as the internet. Forensic triage means assessing the asset to determine whether it has been compromised.
CISA calculates the KEV due date with the same table, using its own evidence on whether the vulnerability is present in a publicly exposed asset. Each agency makes the final exposure decision for each of its assets.
Affected Products
| Vendor | Product | Affected versions |
|---|---|---|
| Edimax | Edimax IC-7100 IP Camera | All |
Solutions and Workarounds
from the CNA's CVE recordWorkarounds
Edimax has not responded to CISA requests to coordinate the vulnerability. Affected users are encouraged to reach out to Edimax customer support https://www.edimax.com/edimax/form/contact_us/data/edimax/global/contact_us/ .
References
1 linksOther references
Record Details
- Published
- 2025-03-04
- Last updated
- 2025-10-21
- Assigner (CNA)
- icscert
- Credited to
- Akamai SIRT reported this vulnerability to CISA.
More from Edimax
CVE record data © The MITRE Corporation, used under the CVE Terms of Use. Exploited-in-the-wild data from the CISA Known Exploited Vulnerabilities catalog (CC0). Exploit prediction scores by FIRST EPSS (first.org/epss). Alert titles and links from CISA cybersecurity alerts. This site is not affiliated with or endorsed by MITRE, NVD, CISA, or FIRST.