CVE-2026-9514
CVE-2026-9514 is a medium-severity vulnerability in Totolink CA750-PoE (CVSS 4.0 CVSS-B score 5.3), classified as CWE-78 (OS Command Injection). It is not in the CISA Known Exploited Vulnerabilities catalog, and CISA's SSVC assessment rates its exploitation as proof of concept. As of 2026-11-22, EPSS estimates a 10.4% probability of exploitation in the next 30 days, in the 95th percentile of scored CVEs.
Updated
Description
A security vulnerability has been detected in Totolink CA750-PoE 6.2c.510. Impacted is the function setNetworkDiag of the file /cgi-bin/cstecgi.cgi of the component Setting Handler. The manipulation of the argument NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop is directly passed by the attacker/so we can control the NetDiagHost/NetDiagPingNum/NetDiagPingSize/NetDiagPingTimeOut/NetDiagTracertHop leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used.
Key Findings
as of 2026-11-22- Its current EPSS score (10.4%) is higher than that of 25% of CISA KEV entries.
Severity
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:POpen in CVSS calculator CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:ROpen in CVSS calculator CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:ROpen in CVSS calculator AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:ND/RC:URRemediation Timeline
BOD 26-04, US federal agenciesIf CISA adds it to the KEV catalog: 14 days on a publicly exposed asset, 14 days on other assets.
Deadlines for US federal civilian agencies under Table 1 of CISA BOD 26-04, from the CVE's KEV status (not listed) and CISA's SSVC values (automatable no, technical impact partial, 2026-05-26).
How the timeline is set
Table 1 of CISA's Binding Operational Directive 26-04 sets the time US federal civilian agencies have to remediate a vulnerability. It depends on four inputs: whether the asset is publicly exposed, whether the CVE is in the KEV catalog, whether an adversary can automate its exploitation, and whether exploitation gives partial or total control of the asset, which SSVC calls technical impact. CISA publishes the last three for every CVE through services such as its Vulnrichment program.
Days are calendar days. The clock starts at whichever comes first: CISA adds the CVE to the KEV catalog, or the agency identifies the vulnerability on an asset and reports it to its Continuous Diagnostics and Mitigation (CDM) dashboard. A publicly exposed asset is accessible to unauthenticated or untrusted entities via public networks, such as the internet. Fix on system upgrade means remediating the next time the asset receives a scheduled major upgrade or rebuild.
If CISA adds the CVE to the KEV catalog, the timeline shortens.
Affected Products
| Vendor | Product | Affected versions |
|---|---|---|
| Totolink | Totolink CA750-PoE | 6.2c.510 |
References
5 linksExploits & PoCs
Third-party advisories
Technical writeups
Detection signatures
Product pages
Record Details
- Published
- 2026-05-25
- Last updated
- 2026-05-26
- Assigner (CNA)
- VulDB
- Credited to
- Buoy_yes (VulDB User)
More from TOTOLINK
Totolink CA750-PoE Setting cstecgi.cgi setUnloadUserData os command injection
Totolink CA750-PoE Setting cstecgi.cgi setUpgradeUboot os command injection
Totolink CA750-PoE Setting cstecgi.cgi setUploadUserData os command injection
Totolink CA750-PoE Setting cstecgi.cgi recvUpgradeNewFw os command injection
CVE record data © The MITRE Corporation, used under the CVE Terms of Use. Exploited-in-the-wild data from the CISA Known Exploited Vulnerabilities catalog (CC0). Exploit prediction scores by FIRST EPSS (first.org/epss). Alert titles and links from CISA cybersecurity alerts. This site is not affiliated with or endorsed by MITRE, NVD, CISA, or FIRST.